TVX-2000 X射線測量儀 型 號:TVX-2000X- ray imaging scope TVX-2000X- ray imaging scope(TVX-2000) is world"s first portable X-Ray imaging scope. The X-scope enables you to view all types of inner structures, human body, animals and other types on its screen. The X-scope is an essential equipment for Laboratories, Hospitals, Vet. Hospitals, and Industrial Fields. Economic and Portable (2.5 kg) With a portable battery, The user can monitor X-ray motion images for two hours and the user can save and send images through internet and laptop. Safe equipment that can be used by everyone By totally improving the defects of conventional X-ray level (Below the user declaration level) lower than the safety limit of NRC, the user does not need to wear protective gears such as radioactive badge, lead apron, and shielding. Various application The images can be connected to Polaroid camera, 35mm general camera and CCD camera which enables the user to watch through video monitor or TV and the images can also be saved, edited and analyzed with the computer.Field of Application X-scope can be used for many purpose: Security Check, Vet Hospital, Emergency room, 911 Rescue Sports Medicine, Inspection of parts in various industry, Corrosion check for pipes, Check for Semiconductor and Multilayer PCB.Specification View field: ø 50 mmImage resolution: 8 Lp/mmPortable battery operation (input power:DC 15.6 V)Radiation source: x-ray tube (40KV, 〈0.1mA)Radiation: less than 0.05 mR/hCompatible : Polaroid /35 mm camera, CCDcamera & monitor systemvideo system, video printer,Temperature: 060Humidity:595%R.H.Dimensions: 38cm(L)×13cm(W)×8cmH
簡介 440RF/D是一種高靈敏度、低能輻射屏蔽的泄露監(jiān)測儀,其設計是基于CMOS微處理器技術,可以快速、地檢測天然本底和低劑量輻射,通過了電器工業(yè)協(xié)會認證。監(jiān)測儀符合美國衛(wèi)生教育和福利部標準(U.S. Department of HEW)中21 CFR 1020.10條款,對電視接收器輻射泄露檢測所必需的靈敏性和測量角度的要求,即在距離接收器外表面任何5cm處的輻射劑量率不得超過0.5 mR/h。應用 電視機行業(yè)中測量輻射泄漏的基本儀器 存在輻射的雷達和發(fā)射塔的測量 - 陰極射線管(CRT)輻射泄漏的檢測 - 高射頻場應用最理想 - 能夠測量低到12 keV的輻射劑量率特征 - 滿足21 CFR 1020.10條款電視接收器和21 CFR 1020.40條款箱式X射線系統(tǒng)的輻射監(jiān)測要求 - 對10 mW/cm2 輻射不靈敏 - 對15 keV的X射線的分辨力仍能保持0.02 mR/h - 自動回零 - CMOS設計其穩(wěn)定性和優(yōu)良的使用表現(xiàn) - 電池易于裝卸 - 可以使用SI單位規(guī)格 檢測范圍:大于150keV的β射線,大于12keV的γ射線和X射線 RF 響應:對高到20 mW/cm2 輻射沒有響應 工作量程:440RF/D的照射率有5個量程,0-1、0-3, 0-10、0-30、和0-100 mR/h; 440RF/D-SI的劑量當量照射率也有5個量程,0-10、0-30、0-100、0-300、和0-1000 µSv/h 響應時間:達到各量程的90%時的響應時間如下表:工作量程 響應時間(秒) 0-1 mR/h (0-10 µSv/h) 7 0-3 mR/h (0-30 µSv/h) 7 0-10 mR/h (0-100 µSv/h) 5 0-30 mR/h (0-300 µSv/h) 5 0-100 mR/h (0-1000 µSv/h) 3 精度:在不考慮能量響應的影響時,在任何量程的10 - 100%之間,精度在10%以內。儀器精度的校準點在21keV的X射線(27.5 KVCP, 0.9 mmA/HVL) 趨向性:任何方向上在滿刻度的2%以內 典型的能量關系:對γ和X射線,從12.5 - 42 keV在10%以內;100 keV 時最大響應峰在+40%;用外加的平衡壁在 137Cs 和 60Co 下,在10%之內 使用環(huán)境溫度:20到40°C 使用環(huán)境濕度:0到95%, 無冷凝 壓力相關性:內部軟件控制的壓力傳感器和溫度傳感器,會自動對未密封的電離室從70到106 kPa進行標準空氣密度修正因子的壓力修正 初始化穩(wěn)定性:約30秒 探 測 器:內部電離室直徑3.56 cm,長5.87 cm,橫截面積10 cm2,鋁涂覆的聚酯薄膜窗口厚1.5 mg/cm2;鎂制外窗厚13 mg/cm2。電離室中心到三個塑料緩沖器頂點所確定的平面之間的距離為5cm。 顯 示:標有0-3和0-10的3.7 in(9.5 cm)監(jiān)測器 電 源:5節(jié)9V 電池,可以工作200 hr。其中3節(jié)電池并聯(lián)作為電源,另2節(jié)串聯(lián)電池作為-18V 電離室偏壓 控 制:單向旋轉鈕控制電源和量程轉換,內裝彈簧的開關用于校準源 調 零:自動回零 檢 驗 源:內置的標準鈾源提供了持久一致的校準結果 結 構:防濺濕,全金屬外殼 尺 寸:12.7 × 20.3 × 27.6 cm 重 量:3.1 kg 運輸體積:0.071 m3 運輸重量:6.05 kg